Topcon GPT-2003 Instrukcja Użytkownika Strona 94

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 168
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 93
8 LAYOUT
8-5
8.1.3 Setting Occupied Point
Occupied point can be set by two setting methods as follow.
1) Setting from the coordinate data stored in the internal memory.
2) Direct key input of coordinate data.
Example setting :Setting the occupied point from the internal coordinate data le
Operating procedure Operation Display
1 Press the [F1](OCC.PT INPUT) key from the
Layout menu 1/2.
The previous data is shown.
[F1]
2 Press the [F1] (INPUT) key and enter PT#. *1)
Press the [F4](ENT) key.
[F1]
Enter PT#
[F4]
3 Enter INS.HT in the same way.
[F1]
Enter
INS.HT
[F4]
The display returns to layout menu 1/2.
*1) Refer to Section 2.6 “How to Enter Alphanumeric characters”.
OCC.PT
PT#:
INPUT LIST NEZ ENTER
OCC.PT
PT#=PT-01
1234 5678 90.– [ENT]
INSTRUMENT HEIGHT
INPUT
INS.HT: 0.000 m
INPUT ––– ––– [ENT]
1234 5678 90.– [ENT]
LAYOUT 1/2
F1:OCC.PT INPUT
F2:BACKSIGHT
F3:LAYOUT P
Przeglądanie stron 93